0,1012013100,300,0,"occurrances","ISUP: CHAN MATE UNAVAILABLE","ss7svc4"
A comma separates each field. Table A-4 describes the content of each field.
Table A-4 Archived Measurement File Fields
Field Name Data Type
Maximum
Length Comments
Release level Integer 3 Format of records (should be set to 0).
Timestamp
(seconds)
Integer 10 Indicates the time, in seconds, since the start of the
UNIX internal timer, time of epoch.
Time interval
(seconds)
Integer 5 Duration of the collection interval.
Measurement
value
Integer 10 Value of the measurement.
Measurement
units
String 32 The type of measurement unit that is recorded.
Measurement
category
String 32 Text that describes the nature of the measurement. For
a list and description of the available measurement, see
Appendix D, “Cisco PGW 2200 Softswitch
Measurements.”
Component name String 32 Identifies the component that is associated with the
alarm. For more information on components, see
Cisco PGW 2200 Softswitch Release 9.8 Provisioning
Guide.