Specifications
3-23
Cisco MGX 8260 Command Line Interface Guide
Release 1.2, Part Number 78-10987-01 Rev. B0, January, 2002
Chapter 3 Card Management
Upgrading Software Images
2. Log in as superuser or a user with level 1 privileges.
3. Follow the upgrade procedures for each card type.
–
See the “Upgrading SCC Software” section on page 3-23 for SCC upgrade procedures.
–
See the “Upgrading BSC Software” section on page 3-24 for BSC upgrade procedures.
–
See the “Upgrading NSC Software” section on page 3-26 for NSC upgrade procedures.
4. Log out of your Telnet session.
Note We recommend that you use the upgrade procedures while simultaneous console connections are
established to both the active and the standby SCC.
Upgrading SCC Software
The upgrade process for redundant SCCs is graceful. It does not interrupt established calls, but it can
interrupt calls in the process of being established. When you invoke the upgrade process, the MGX 8260
upgrades and restarts the standby SCC. You can then commit or cancel the upgrade. When you commit
the software, the MGX 8260 switches to the standby SCC and then upgrades the other SCC.
Warning
Upgrading nonredundant cards interrupts service. Perform nonredundant upgrades
during light traffic periods or during a prearranged maintenance window.