Specifications

9-357
Cisco MGX 8260 Command Line Interface Guide
Release 1.2, Part Number 78-10987-01 Rev. B0, January, 2002
Chapter 9 Command Reference
onbertds1
onbertds1
Start BERT on DS1.
onbertds1 Location Pattern Rate DS0 StateCtrl
Syntax Description
Defaults No default behavior or values.
Location The slot and line number, delimited by a period, of the DS1 line.
Pattern One of the following patterns. Values: 1-13.
1 = Randomly-generated 2
9
-1
pattern
2 = Randomly-generated 2
11
-1
pattern
3 = Randomly-generated 2
15
-1
pattern
4 = Randomly-generated 2
20 -1
pattern with QRSS
5 = Randomly-generated 2
20 -1
pattern
6 = Randomly-generated 2
23 -1
pattern
7 = Repetitively-generated all
-1
pattern
8 = Repetitively-generated all
-1
pattern
9 = Repetitively-generated alternating 1 and 0 pattern
10 = Repetitively-generated alternating 11 and 00 pattern
11 = Repetitively-generated 1 in 24 pattern
12 = Repetitively-generated 1 in 16 pattern
13 = Repetitively-generated 1 in 8 pattern
Rate The error rate to be injected into the pattern during BERT test. The value is
used as the exponent in the formula, BER 10-x. For example, if x = 1, the
error rate is 10-1 or 10%. If the rate is 0, no error is injected in the BERT
pattern. Values: 1-8 as follows:
1=No Error Rate Injection.
2=0.1
3=0.01
4=0.001
5=0.0001
6=0.00001
7=0.000001
8=0.0000001
Ds0 A bit-mask specifying which DS0s are going to participate in the Bert test.
StateCtrl A integer to control starting and stopping the Bert test. Values:
1=Start Bert test.
2=Stop Bert test.