Specifications
9-249
Cisco MGX 8260 Command Line Interface Guide
Release 1.2, Part Number 78-10987-01 Rev. B0, January, 2002
Chapter 9 Command Reference
lsemm
lsemm
List sensor environmental monitoring data.
lsemm UnitID SensorType SensorID
Syntax Description
Defaults No default behavior or values
Command Modes Security level 6
Command History
UnitID The unit identifier:
1=slot1
2=slot2
3=slot3
4=slot4
5=slot5
6=slot6
7=slot7
8=slot8
9=slot9
10=slot10
11=slot11
12=slot12
13=slot13
14=slot14
15=slot15
16=slot16
100=chassis
SensorType Temperature, fan, or voltage sensor. Values: 1 - 3, respectively. Fan (3) is
valid only with the chassis unit ID (100). For more information, see
“Monitoring Environmental Alarms” section on page 6-19
SensorID The identifier that is usually on the top or bottom of the card, or next to the
CPU. Values: an integer.
Release Modification
1.0 This command was first introduced.