Specifications

9-116
Cisco MGX 8260 Command Line Interface Guide
Release 1.2, Part Number 78-10987-01 Rev. B0, January, 2002
Chapter 9 Command Reference
chsonetalm
chsonetalm
Change SONET alarm thresholds.
chsonetalm Location [redSeverity yellow Severity perfSeverity SeCV15MinThresh
SeCV24HrThresh SeES15MinThresh SeES24HrThresh SeSES15MinThresh SeSES24HrThresh
SeSEFS15MinThresh SeSEFS24HrThresh LCV15MinThresh LCV24HrThresh
LES15MinThresh LES24HrThresh LSES15MinThresh LSES24HrThresh LUAS15MinThresh
LUAS24HrThresh PCV15MinThresh PCV24HrThresh PES15MinThresh PES24HrThresh
PSES15MinThresh PSES24HrThresh PUAS15MinThresh PUAS24HrThresh]
Location The slot and line number, delimited by a period, of the OC-3 line.
Valid slot: 9. Valid lines: 1-4
redSeverity The red alarm severity:
1=Minor (reserved for future use)
2=Major
yellowSeverity The yellow alarm severity:
1=Minor
2=Major (reserved for future use)
perfSeverity The performance alarm severity:
1=Minor
2=Major (reserved for future use)
SeCV15MinThresh The section threshold for code violations in a 15-minute or sliding 24-hour
window. Code violations are Bit Interleaved Parity errors detected in the
incoming signal.
SeCV24HrThresh
SeES15MinThresh The section threshold for errored seconds in a 15-minute or sliding 24-hour
window. An errored second is a second with one or more code violations at
that layer or incoming defects.
SeES24HrThresh
SeSES15MinThresh The section threshold for severely errored seconds in a 15-minute or sliding
24-hour window. A severely errored second is one in which code violations
or incoming defects occurred.
SeSES24HrThresh
SeSEFS15MinThresh The section threshold for severely errored frame seconds in a 15-minute or
sliding 24-hour window. A SEFS is a second containing one or more SEF
events.
SeSEFS24HrThresh
LCV15MinThresh The line threshold for code violations in a 15-minute or sliding 24-hour
window. Code violations are Bit Interleaved Parity errors detected in the
incoming signal.
LCV24HrThresh
LES15MinThresh The line threshold for errored seconds in a 15-minute or sliding 24-hour
window. An errored second is a second with one or more code violations at
that layer or incoming defects.
LES24HrThresh
LSES15MinThresh The line threshold for severely errored seconds in a 15-minute or sliding
24-hour window. A severely errored second is one in which code violations
or incoming defects occurred.
LSES24HrThresh
LUAS15MinThresh The line threshold for unavailable seconds in a 15-minute or sliding 24-hour
window. Unavailable seconds represent the number of seconds that the
interface is unavailable.