Specifications

9-62
Cisco MGX 8260 Command Line Interface Guide
Release 1.2, Part Number 78-10987-01 Rev. B0, January, 2002
Chapter 9 Command Reference
che1alm15
che1alm15
Change 15-minute E1 alarm thresholds.
che1alm15 Location [LCV_15 LES_15 UAS_15 FE_ESR_15 FE_SESR_15 FEBE_ESR_15
FEBE_SESR_15 CRC_ESR_15 CRC_SESR_15 ES-ESR_15 SES_ESR_15 ES_15 SES_15
BE_15 PCV_15 CSS_15]
Syntax Description
Defaults No default behavior or values. The following defaults apply to a new E1 line:
LCV_15: 14
LES_15: 12
UAS_15: 10
FE_ESR_15: 800
FE_SESR_15: 20
FEBE_ESR_15: 800
FEBE_SESR_15: 20
CRC_ESR_15: 800
Location The slot and line number, delimited by a period, of the DS1 line
LCV_15 The threshold for LCV (Line Code Violations). A code violation is either a
bipolar violation or excessive zeroes event.
LES_15 The threshold for LES (Line Errored Seconds). An errored second is any
second with at least one code violation.
UAS_15 The threshold for UAS (Unavailable Seconds). UAS represents the number
of seconds that the interface is unavailable in a fixed measurement interval.
FE_ESR_15 The far end threshold for ESR (Errored Seconds Ratio) due to framing
errors. ESR is the ratio of errored seconds to total seconds in a fixed
measurement interval.
FE_SESR_15 The far end threshold for SESR (Severely Errored Seconds) due to framing
errors. SESR is the ratio of severely errored seconds to total seconds in a
fixed measurement interval.
FEBE_ESR_15 The far end block error threshold for ESR.
FEBE_SESR_15 The far end block error threshold for SESR.
CRC_ESR_15 The threshold for ESR resulting from CRC errors.
CRC_SESR_15 The threshold for SESR resulting from CRC errors.
ES-ESR_15 The threshold for ESR resulting from ES errors.
SES_ESR_15 The threshold for ESR resulting from SES errors.
ES_15 The threshold for ES (Errored Seconds).
SES_15 The threshold for SES (Severely Errored Seconds).
BE_15 The threshold for BE (Burst Errors)
PCV_15 The threshold for PCV (Path Coding Violations)