Specifications

7-7
Cisco MGX 8260 Command Line Interface Guide
Release 1.2, Part Number 78-10987-01 Rev. B0, January, 2002
Chapter 7 Performance Monitoring
Monitoring E1 Performance
The system displays the 24-hour statistics summary:
============================================================================
E1 Total Stats (lse1totsts)
============================================================================
Slot.Line ErrSecs SeverErrSecs SlipSecs UnAvailSecs LineErSecs
========= ======= ============ ============ =========== ==========
3.1 2 0 2 0 0
3.2 2 0 2 0 0
3.3 2 0 2 0 0
3.4 2 0 2 0 0
Viewing Interval E1 Statistics
Interval statistics are collected by each E1 Interface for the previous 24 hours of operation. The
24 hours are broken into 96 15-minute intervals, where interval 1 is the most recent and 96 is the oldest.
As time progresses, the system drops the oldest interval and adds the latest one, creating a sliding
24-hour window that moves with time.
To list interval statistics for an E1 line, enter the lse1intst command, specifying the slot and line
number, delimited by a period, of the line and the number (1-96) of the interval of interest.
The system displays the interval statistics:
=======================================================================
E1 Line Interval Statistics (lse1intst)
=======================================================================
E1 Slot.Line : 3.1
Interval : 1
Path Errored Seconds : 0
Path Severely Errored Seconds : 0
Path UnAvailable Seconds : 0
Path Control Slip Seconds : 0
Path Code Violations : 0
Path Bursty Errored Seconds : 0
Line Errored Seconds : 0
Line Code Violations : 0
Errored Seconds Ratio : 0
Severely Errored Seconds Ratio : 0
Frame Error Errored Seconds : 0
Severly Errored Frame Error Seconds : 0
Far End Unavailable Error Seconds : 0
ESR by Far End Errors : 0
SESR by Far End Errors : 0
Unavailable Errored CRC Seconds : 0
Errored CRC Seconds : 0
Severely Errored CRC Seconds : 0
ESR Caused by CRC Errors : 0
SESR Caused by CRC Errors : 0
Far End Block Errors : 0
Severely Errored Secs by Far End Errors : 0
Unavailable Seconds by Far End Block Errors: 0
ESR by Far End Block Errors : 0
SESR by Far End Block Errors : 0