Specifications

6-32
Cisco MGX 8260 Command Line Interface Guide
Release 1.2, Part Number 78-10987-01 Rev. B0, January, 2002
Chapter 6 Alarm Surveillance
Working With Traps
Card Traps
The following table summarizes the alarm conditions and corresponding trap numbers for card alarms:
DS1 Traps
The following table summarizes the alarm conditions and corresponding trap numbers for DS1 alarms:
Table 6-12 Card Traps
Event Severity Trap Number
Card inserted Info 1100
Card removed Info 1101
Card failed Major 1102
Core card switchover Major 1103
Service card switchover Minor 1104
Card major alarm Major 1105
Card minor alarm Minor 1106
Card alarm cleared Info 1107
Card active Info 1108
Core redundancy failed Major 1109
Service module redundancy failed Major 1110
Multiservice Media module major alarm Major 1111
Physical card mismatched Minor 1112
Physical card configuration cleared Info 1113
Card in standby Info 1114
Physical back card inserted Info 1115
Physical back card removed Info 1116
DMC map added Info 2000
DMC map deleted Info 2001
DMC map modified Info 2002
DSP minor alarm (1 DSP down) Major 2101
DSP major alarm (all DSPs down) Major 2102
Ta b l e 6 - 1 3 D S 1 Tr a p s
Event Severity Trap Number
DS1 line added Info 1300
DS1 line deleted Info 1301
DS1 line modified Info 1302
DS1 line major alarm Major 1303
DS1 line minor alarm Minor 1304