Specifications

6-23
Cisco MGX 8260 Command Line Interface Guide
Release 1.2, Part Number 78-10987-01 Rev. B0, January, 2002
Chapter 6 Alarm Surveillance
Surveillance Tasks for Alarms
The system displays the following information:
=======================================================================
Environment Monitoring Module Reading (lsemm)
=======================================================================
EMM UnitId : slot11
EMM SensorType : temp-celsius
EMM SensorID : 1
EMM Alarm Status : clear
EMM Sensor Reading : 30 temp-celsius
Maj Alarm Hi Threshold : 75
Maj Alarm Lo Threshold : -5
Min Alarm Hi Threshold : 70
Min Alarm Lo Threshold : 0
See the Voltage Sensor Listing, page 6-21 for a description of the table.
Fan Sensor Listing
To view the fan sensor 1 information, enter the following command:
lsemm chassis 1 1
The system displays the following information:
=======================================================================
Environment Monitoring Module Reading (lsemm)
=======================================================================
EMM UnitId : chassis
EMM SensorType : fan-rpm
EMM SensorID : 1
EMM Alarm Status : clear
EMM Sensor Reading : 3308 fan-rpm
Maj Alarm Hi Threshold : 9999999
Maj Alarm Lo Threshold : 2900
Min Alarm Hi Threshold : 9999999
Min Alarm Lo Threshold : 3100
See the Voltage Sensor Listing, page 6-21 for a description of the table.