Specifications

6-22
Cisco MGX 8260 Command Line Interface Guide
Release 1.2, Part Number 78-10987-01 Rev. B0, January, 2002
Chapter 6 Alarm Surveillance
Surveillance Tasks for Alarms
The system displays the following information:
=======================================================================
Environment Monitoring Module Reading (lsemm)
=======================================================================
EMM UnitId : slot11
EMM SensorType : voltage-mvolt
EMM SensorID : 1
EMM Alarm Status : clear
EMM Sensor Reading : 4970 voltage-mvolt
Maj Alarm Hi Threshold : 5500
Maj Alarm Lo Threshold : 4500
Min Alarm Hi Threshold : 5300
Min Alarm Lo Threshold : 4700
Temperature Sensor Listing
To view the temperature sensor 1 information for slot 11, enter the following command:
lsemm slot11 1 1
Displayed Information Description
EMM UnitId The slot or chassis with the sensor
EMM SensorType The type of environmental sensor
EMM SensorID The number of a sensor on a unit
EMM Alarm Status The status of the environmental alarm:
clear
minor
major
EMM Sensor Reading The sensor reading:
Temperature in degrees celsius
Chassis voltage in volts
Fan speed in rpm
Maj Alarm Hi Threshold The threshold value separating a major alarm
from a minor alarm for high readings
Maj Alarm Lo Threshold The threshold value separating a minor alarm for
a high reading from normal operation
Min Alarm Hi Threshold The threshold value separating a major alarm
from a minor alarm for a low reading
Min Alarm Lo Threshold The threshold value separating a minor alarm for
a low reading from normal operation