Specifications

6-15
Cisco MGX 8260 Command Line Interface Guide
Release 1.2, Part Number 78-10987-01 Rev. B0, January, 2002
Chapter 6 Alarm Surveillance
Surveillance Tasks for Alarms
Setting DS3 Alarm Thresholds
The chds3alm command changes the configuration settings for alarm severity, integration period, and
thresholds for various error conditions, such as LCV, LES, and LSES. The performance alarm is set if
the DS3 errors exceed any of the threshold counts set by this command. To change alarm threshold
values, enter the chds3alm command as described in the “chds3alm” section on page 9-56.
Monitoring Fast Ethernet Alarms
Fast Ethernet lines raise an alarm when an active line goes down, and invoke informational events for
line configuration changes.
To view the information for configured Fast Ethernet lines, enter the lsethlns command. The system
lists summary information for all Fast Ethernet lines:
=======================================================================
Ether Lines (lsethlns)
=======================================================================
Line IP Address Subnet Mask Status Gateway Addr
====== =============== =============== ================ ===============
9.1 12.18.6.12 255.255.255.0 active 12.18.6.1
9.2 12.18.7.11 255.255.255.0 inactive 12.18.7.1
Monitoring OC-3 Alarms
This section describes viewing OC-3 alarm and line status, and setting and viewing alarm thresholds.
Viewing OC-3 Alarms
To view OC-3 alarm severity, follow these steps:
Step 1 List alarm information using the lssonetalms command.
Displayed Information Description
Line The slot and line number for the Fast Ethernet line
IP Address The IP address for the Fast Ethernet line
Subnet Mask The IP address mask for the Fast Ethernet line
Status The operational status for the line, as follows:
active
inactive
failed
link down in active state
link down in inactive state
Gateway Addr The primary IP gateway for this line