Specifications

6-7
Cisco MGX 8260 Command Line Interface Guide
Release 1.2, Part Number 78-10987-01 Rev. B0, January, 2002
Chapter 6 Alarm Surveillance
Surveillance Tasks for Alarms
Setting DS1 Alarm Thresholds
This command changes the configuration settings for alarm severity, integration period, and thresholds
for various error conditions, such as LCV, LES, and LSES. The performance alarm is set if the line
errors exceed any of the threshold counts set by this command.
To change alarm threshold values, enter the chds1alm command as described in the “chds1alm” section
on page 9-47.
LSES 24 24 hour severely errored seconds 100
PCV 15 15 minute path coding violations 35
PCV 24 24 hour path coding violations 50
PES 15 15 minute path errored seconds 35
PES 24 24 minute path errored seconds 50
PSES 15 15 minute path severely errored seconds 35
PSES 24 24 hour path severely errored seconds 50
SEFS 15 15 minute severely errored framing seconds 2
SEFS 24 24 hour severely errored framing seconds 17
PSAS 15 15 minute alarm indication signal seconds 2
PSAS 24 24 hour alarm indication signal seconds 17
UAS 15 15 minute unavailable seconds 10
UAS 24 24 hour unavailable seconds 10
BES 15 15 minute bursty errored seconds 35
BES 24 24 hour bursty errored seconds 50
PCSS 15 15 minute path controlled slip seconds 35
PCSS 24 24 hour path controlled slip seconds 50
Table 6-1 DS1 Performance Alarm Thresholds (continued)
Threshold Description Default