Specifications
6-4
Cisco MGX 8260 Command Line Interface Guide
Release 1.2, Part Number 78-10987-01 Rev. B0, January, 2002
Chapter 6 Alarm Surveillance
Surveillance Tasks for Alarms
Monitoring Card Alarms
Card alarms provide information on card operation and events.
Viewing Card Alarms
To view card alarms, follow these steps:
Step 1 List information for a card using the lscd command, and specifying the slot location of the card.
The system displays the card information.
=======================================================================
Physical Card Entry (lscd)
=======================================================================
Physical Card Number : 11
Logical Card Number : 11
Front Card Type : bsc
Back Card Type : dmcBsc6T3
Daughter Card 1 Type : bim4T3E3
Daughter Card 2 Type : *
Card State : active
Card Service : 0
Hardware Revision : 1
Firmware Revision : BSC_B_r01.01.b1
Software Revision : BSC_r01.01.b1
Front Card Serial # : bsc-093
Back Card Serial # : t3e3-141
Fab Version :
Failure Reason : failResonNone
Reset Reason : watchDogReset
Mismatch Reason : noMismatch
Integrated line alarm state : Clear
Line performance alarm state : Clear
EMM temperature alarm state : Clear
EMM voltage alarm state : Clear
SW error alarm state : Clear
Component failure alarm state : Clear
ATM Queue Profile # : 1
RAM Backup : disabled
Interface Mode : bkcd led
Interface Mode : bkcd
Step 2 Check the alarm fields for alarm indications. The alarm types vary somewhat by card type.
Step 3 Clear any active alarms as described in the “Clearing Alarms” section on page 8-6.