Specifications
6-2
Cisco MGX 8260 Command Line Interface Guide
Release 1.2, Part Number 78-10987-01 Rev. B0, January, 2002
Chapter 6 Alarm Surveillance
Surveillance Tasks for Alarms
Monitoring Shelf Alarms
Shelf alarms provide information on environmental, clock, and software operation. When checking
alarms, start with commands that list summary information. Then use commands that provide details
about the event or condition interest.
Step 1 To view shelf alarms, enter the lsalms command.
Step 2 Interpret the listing as follows:
=========================================================================
Shelf Alarms (lsalms)
=========================================================================
Shelf Card Error : false
Shelf Software Error : false
Shelf Integrated Alarm : major
Slot 1 : Clear
Slot 2 : Major
Slot 3 : Clear
Slot 4 : Clear
Slot 5 : Clear
Slot 6 : Major
Slot 7 : Clear
Slot 8 : Clear
Slot 9 : Clear
Slot 10 : Clear
Slot 11 : Major
Slot 12 : Clear
Slot 13 : Clear
Slot 14 : Clear
Slot 15 : Clear
Slot 16 : Clear
Card : Major
Chassis Temperature : Clear
Voltage : Clear
Fan : Clear
Shelf Alarm History : major
Displayed Information Description
Shelf Card Error Shelf card error indication:
• true
• false
Shelf Software Error Shelf software error indication:
• true
• false
Shelf Integrated Alarm The shelf integrated alarm indicates the combined
alarm condition for all shelf, card, line, and EMM
alarms. Valid states:
• clear
• major
• minor
• info