Datasheet
5
Catalyst 6500 Series Supervisor Engine 1A DRAM Upgrade Installation Note
78-14357-02
Removing the MSFC2
To remove the MSFC2 from the supervisor engine, follow these steps:
Step 1 Upload the current configuration to a server. On any modules running Cisco IOS software, save the
running configuration.
Step 2 Remove the supervisor engine from the Catalyst 6500 series switch. (Refer to the Catalyst 6500 Series
Module Installation Guide for removal instructions.)
Step 3 Place the supervisor engine on an antistatic mat or foam.
Step 4 Remove the securing screws and cap nut that secure the MSFC2 to the supervisor engine. (See Figure 1
for an MSFC2 shipped before November 2001, or see Figure 2 for an MSFC2 shipped after November
2001.)
Note The MSFC2 shipped after November 2001 is physically smaller than the previous MSFC2 and
is not secured with a cap nut. (See Figure 2.)
Figure 1 MSFC2 Shipped Before November 2001—Removing Securing Screws and Cap Nut
73810
SUPERVISOR ENGINE I I I
CONSOLE
SWITCH LOAD
1%
100%
ACTIVE
ACTIVE
ACTIVE
RESET
SLOT 0
WS-X5530
Hold here
Hold here