Catalyst 6500 Series Supervisor Engine 1A DRAM Upgrade Installation Note
78-14357-02
Installing the MSFC2
Figure 12 MSFC2 Shipped After November 2001—Installing the Securing Screws
Step 6
Install the supervisor engine in the Catalyst 6500 series switch. (Refer to the Catalyst 6500 Series
Module Installation Guide for installation instructions.)
Note Verify that the supervisor engine STATUS LED is lit. If the STATUS LED changes from orange
to green, the supervisor engine has successfully completed the boot process and is now online.
If the STATUS LED remains orange or turns red, the supervisor engine has not successfully
completed the boot process and may have encountered an error.
Note If the LEDs on the supervisor engine front panel are red, remove the supervisor engine, carefully
remove the DIMMs, and reseat the DIMMs in the socket. Push the DIMMs firmly back into the
socket until the retainer springs snap into place.
If you have redundant supervisor engines, return to Step 2 in the “Removing the MSFC2” section on
page 4, and follow the directions to upgrade the redundant supervisor engine.
Step 7 Enter the show version command to verify the amount of memory on the supervisor engine.
This example shows that the total memory is 128 MB on the supervisor engine:
Console> show version
...<output truncated>
DRAM FLASH NVRAM
Module Total Used Free Total Used Free Total Used Free
------ ------- ------- ------- ------- ------- ------- ----- ----- -----
2 130944K 57916K 73028K 16384K 12003K 4381K 512K 257K 255K
Console>