Checking the Installation
For AC-input power supplies, the green AC OK LED should go on. For DC-input power supplies, the
green input OK LED should go on. For both types of power supplies, the output fail LED should be off.
Step 2 Listen for the system blower modules or fan trays in the router; you should immediately hear them
operating. In a noisy environment, place your hand in front of the exhaust vents to verify that the blower
modules are operating.
Step 3 During the PRP boot process, observe the PRP alphanumeric display LEDs, which are located at one end
of the PRP, near the ejector lever. (See Figure 8.)
The 4-digit displays show system messages and displays a sequence similar to that shown in Table 6.
Figure 8 PRP Alphanumeric Display LEDs (Vertical View)
1 Upper (or left if horizontal) LED Display 2 Lower (or right if horizontal) LED Display
Table 6 PRP Alphanumeric Display LED Sequences
LED Display Description
MROM
nnnn
PRP microcode loads into MBus random-access memory (RAM); where nnnn
is the microcode version. For example, Microcode Version 1.17 displays as
0117.
1
RP
RDY
The ROMMON for this PRP is enabled and recognized by the system.
ACTV
RP
Cisco IOS is enabled and this PRP is the active PRP.
STBY
RP
Cisco IOS is enabled and this PRP is in standby mode.
70694
PROCESSOR 1 (PRP-1)
1