Specifications

2-45
Cisco ME 3800X and ME 3600X Switch Command Reference
OL-23401-02
Chapter 2 Cisco ME 3800X and ME 3600X Switch Cisco IOS Commands
controller BITS output applique
controller BITS output applique
To configure the Building Integrated Timing Supply (BITS) clock output link type and characteristics,
use the controller BITS output applique command in global configuration mode. To remove the
configuration, use the no form of this command.
controller BITS output applique E1{2048KHz | framing {fas_crc4 | fas_nocrc | |mfas_crc4 |
mfas_nocre} linecode {ami | hdb3}
controller BITS output applique T1 framing {d4 | esf} linecode {ami | b8zs} line-build-out
{0-133ft | 133-266ft | 266-399ft | 399-533ft | 533-655ft}
no controller BITS output applique
Syntax Description
Command Default The default output timing is E1.
Command Modes Global configuration
E1 2048 KHz Specifies an EI timing signal input of 2048 KHz.
E1 framing Specifies an EI signal input and specify the framing mode as one of these
options:
fas_crc4—FASCRC4
fas_nocrc—FAS
mfas_crc4—MFASCRC4
mfas_nocre—MFAS
linecode (E1) Selects the E1 line coding:
ami—AMI encoding
hdb3—HDB3 encoding
T1 framing Specifies a T1 (1.544 MHz) signal input and specify the framing mode as one
of these options:
d4—D4
esf—Extended Superframe
linecode (T1) Selects the T1 line coding:
ami—AMI encoding
b8zs—B8ZS encoding
line-build-out Selects a line length:
0-133ft
133-266ft
266-399ft
399-533ft
533-655ft