Resolved Caveats
• CSCsi78737
The cpmCPURisingThreshold traps on the switch are no longer missing the
cpmProcExtUtil5SecRev and cpmProcessTimeCreated trap components. Note that although the
components were missing from the traps, the PROCESS MIB was still populating the objects.
• CSCsi79504
OSPF hello packets now have the correct CoS value of 7.
• CSCsi85257
A Cisco IP Phone now works correctly when it is connected to a port that is configured with CDP
bypass and multidomain authentication (MDA).
• CSCsj22994
ACLs are now configured correctly when they contain ICMP codes 251 to 255.
• CSCsj47067
If you upgrade from Cisco IOS Release 12.2(35)SE1 to Release 12.2(37)SE, a security violation no
longer occurs when:
–
You enter the switchport port-security maximum 1 vlan access interface configuration
command.
–
An IP phone with a PC behind it is connected to an access port with port security.
• CSCsj53001
The Total- output-drops field in the show interfaces privileged EXEC command output now
displays accurate ASIC drops.
• CSCsj64882
When IGMP snooping is enabled, CGMP interoperability mode now works as it should when the
upstream multicast router is set up correctly with PIM and IP CGMP.
• CSCsj77933
If you enter a space before a comma in the define interface-range or the interface range global
configuration command, the space before the comma is now saved in the switch configuration.
• CSCsj87991
A switch configured for Link Layer Discovery Protocol (LLDP) now correctly reports the enabled
switch capabilities in the LLDP type, length, and value (TLV) attributes.
• CSCsk34118
On a switch with routed ports, when you configure MAC address-table aging time by entering the
mac address-table aging-time time global configuration command and then enter the show
running-config privileged EXEC command, the output no longer displays the aging time values for
internal VLANs.
• CSCsk38083
When UDLD is enabled on a Layer 2 interface, and the native VLAN for the port is not configured
as a VLAN on the switch, UDLD no longer puts the port into an error-disabled state.
• CSCsk59299
When an egress port shaper policy is configured, the switch now correctly polices the traffic down
to the right bandwidth instead of to the next lower available rate.