Datasheet
Data Sheet
© 2010-2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 5 of 17
Rated line voltage: 100–127 VAC; 50 or 60 Hz
Input current (amps) 1.31 (idle)
2.25 (maximum measured)
7.8 (system rated)
60 (peak inrush current; 4 ms)
Leakage current (mA) 0.94 (idle; maximum measured; system rated)
Power (watts) 154 (idle)
257 (maximum measured)
780 (system rated)
VA rating (VA) 157 (idle)
263 (maximum measured)
797 (system rated)
BTU rating (BTU/hr) 525 (idle)
875 (maximum measured)
2661 (system rated)
Rated line voltage: 200–240 VAC; 50 or 60 Hz
Input current (amps) 0.74 (idle)
1.23 (maximum measured)
3.9 (system rated)
60 (peak inrush current; 4 ms)
Leakage current (mA) 0.94 (idle; maximum measured; system rated)
Power (watts) 151 (idle)
251 (maximum measured)
780 (system rated)
VA rating (VA) 154 (idle)
257 (maximum measured)
797 (system rated)
Input requirements*
BTU rating (BTU/hr) 515 (idle)
855 (maximum measured)
2661 (system rated)
Power supply output power Rated steady-state power 675W
Operating 50 to 95°F (10 to 35°C)
at 0–3000 ft (0–914.4m)
with an altitude de-rating of
1.4°F (0.75°C) per 1000 ft (304.8m)
Nonoperating 50 to 109.4°F (10 to 43°C)
Temperature range
Shipment –40 to 140°F (–40 to +60°C)
Relative humidity (RH;
noncondensing)
Operating
Shipment
8 to 80%
5 to 100%
Maximum altitude 7000 ft 2133m
Acoustic noise Operating minimum L WAd (bels) 6.5
Airflow (cubic feet per
minute)
30 CFM minimum 75 CFM maximum
Remote management IBM IMM with Virtual Media enabled
* Maximum measured values were determined with 25ºC ambient temperature, and your results may vary.
* Idle power: Power drawn with the machine(s) logged into the OS, and no other applications running. Memory, HDDs, optical
drives, and tape drives are not being used.
* Measured maximum power: Maximum measured power is the power drawn by the machine with the CPUs 100-percent used and
memory is used 10 percent more than base usage. The exerciser used is Prime95 (torture test) and can be downloaded from
www.mersenne.org.
* Rated system maximum: The maximum power able to be drawn by the machine according to the system label rating.