Datasheet
Data Sheet
© 2010-2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 11 of 17
Height: 3.346 in. Height: 85.2 mm
Width:
●
With top cover: 17.465 in.
●
With front bezel: 18.976 in.
Width:
●
With top cover: 443.6 mm
●
With front bezel: 482.0 mm
Dimensions (H x W x D)
Depth:
●
EIA flange to rear: 27.480 in.
●
Overall: 28.791 in.
Depth:
●
EIA flange to rear: 698 mm
●
Overall: 729 mm
Weight (maximum) 64 lb 29.03 kg
Rated line voltage: 100–127 VAC; 50 or 60 Hz
Input current (Amps) 1.81 (idle)
3.07 (maximum measured)
7.8 (system rated)
60 (peak inrush current; 4ms)
Leakage current (mA) 0.94 (idle; maximum measured; system rated)
Power (watts) 213 (idle)
353 (maximum measured)
780 (system rated)
VA rating (VA) 218 (idle)
362 (maximum measured)
797 (system rated)
BTU rating (BTU/Hr) 727 (idle)
1206 (maximum measured)
2661 (system rated)
Rated line voltage: 200–240 VAC; 50 or 60 Hz
Input current (amps) 1.1 (idle)
1.84 (maximum measured)
3.9 (system rated)
60 (peak inrush current; 4ms)
Leakage current (mA) 0.94 (idle; maximum measured; system rated)
Power (watts) 224 (idle)
372 (maximum measured)
780 (system rated)
VA rating (VA) 229 (idle)
381 (maximum measured)
797 (system rated)
Input requirements*
BTU rating (BTU/Hr) 764 (idle)
1268 (maximum measured)
2661 (system rated)
Power supply output power Rated steady-state power 675W
Operating 50 to 95°F (10 to 35°C)
at 0–3000 ft (0–914.4 m)
with an altitude de-rating of
1.4°F (0.75°C) per 1000 ft (304.8m)
Nonoperating 50 to 109.4°F (10 to 43°C)
Temperature range
Shipment –40 to 140°F (–40 to +60°C)
RH; noncondensing Operating
Shipment
8 to 80%
5 to 100%
Maximum altitude 7000 ft 2133m
Acoustic noise Operating minimum L WAd (bels) 6.5
Airflow (cubic feet per
minute)
30 CFM minimum 75 CFM maximum
Remote management IBM IMM with Virtual Media enabled