Component Value
System management ports Shared Ethernet port
Eight PCIe non-hot plug slots 2
Height: 1.75 in. (1RU) Height: 43 mm
Width:
17.32 in.
Width:
440 mm
Dimensions (H x W x D)
Depth:
Overall: 22 in.
Depth:
Overall: 559 mm
Weight (maximum) 28 lb 12.7 kg
Rated line voltage: 100-127 VAC; 50 or 60 Hz
Input current (amps) 0.65 (idle)
1.74 (maximum measured)
6.0 (system rated)
40 (peak inrush current; 4 ms)
Leakage current (mA) 0.47 (idle; maximum measured; system rated)
Power (watts) 76 (idle)
196 (maximum measured)
351 (system rated)
VA rating (VA) 78 (idle)
201 (maximum measured)
351 (system rated)
BTU rating (BTU/hr) 259 (idle)
669 (maximum measured)
2047 (system rated)
Rated line voltage: 200-240 VAC; 50 or 60 Hz
Input current (amps) 0.37 (idle)
0.92 (maximum measured)
3.0 (system rated)
40 (peak inrush current; 4 ms)
Leakage current (mA) 0.47 (idle; maximum measured; system rated)
Power (watts) 75 (idle)
192 (maximum measured)
351 (system rated)
VA rating (VA) 77 (idle)
197 (maximum measured)
351 (system rated)
Input requirements
1
BTU rating (BTU/hr) 256 (idle)
656 (maximum measured)
2047 (system rated)
Power supply output power Rated steady-state power 351W
Operating 50 to 95°F (10 to 3C)
at 0-3000 ft (0-914.4m)
with an altitude de-rating of
1.4°F (0.75°C) per 1000 ft (304.8m)
Nonoperating 50 to 109.4°F (10 to 43°C)
Temperature range
Shipment -104 to 14F (-40 to 60°C)
1
Maximum measured values were determined with 77°F (25°C) ambient temperature, and your results may va ry. Idle power:
Power drawn with the machine(s) logged into the OS, and no other applications running. Memory, HDDs, optical drives, and tape
drives are not being used. Measured maximum power: Maximum measured power is the power drawn by the machine with the
CPUs 100-percent used and memory is used 10 percent more than base usage. The exerciser used is Prime95 (torture test); you
can download it at
http://www.mersenne.org Rated system maximum: The maximum power the machine can draw according to the