Specifications

44
Channelized and Electrical Interface Line Card Installation and Configuration
78-16417-02
Configuring and Troubleshooting Line Card Interfaces
Configuring the 1-Port Channelized OC-12/STM-4 (OC-3) Line Card
The following procedure describes how to perform a basic controller configuration. After you verify that
the new line card is installed correctly, enter the privileged EXEC mode with the enable command. The
system prompts you for a password if one is required. Use the configure command to configure the
controller.
A Cisco 12000 Series Router identifies an interface address by its line card slot number and port number,
in the format slot/port. For example, the slot/port address of an interface on an 1-port channelized
OC-12/STM-4 (OC-3) line card installed in line card slot 2 and port 0 is 2/0. Even if the card contains
only one port, you must use the slot/port notation.
Use the following procedure to configure the 1-port channelized OC-12/STM-4 (OC-3) line card. Press
the Enter key after each configuration step unless otherwise noted.
Step 1 Confirm that the system recognizes the card by entering the show version command:
Router# show version
Step 2 Check the status of each port by entering the show interface command:
Router# show interface
Step 3 Enter configuration mode and specify that the console terminal will be the source of the configuration
subcommands:
Router# configure terminal
Router(config)#
Step 4 In global configuration mode, enter the controller configuration mode by entering the controller
command and specifying an OC-12/STM-4 interface, as follows:
Router(config)# controller SONET 1/0
Router(config-controller)#
Thresholds [no] ber-threshold b1-tca [3..9]
[no] ber-threshold b2-tca [3..9]
[no] ber-threshold sd-ber [3..9]
[no] ber-threshold sf-ber [3..9]
6(10e-6)
6(10e-6)
6(10e-6)
3(10e-6)
Alarm Reporting [no] alarm-report [b1-tca | b2-tca |
lais | lrdi | sd-ber | sf-ber | slof | slos]
b1-tca, b2-tca, sf-ber, slos, slof
Shutdown [no] shutdown no shutdown
1. Scrambling is always enabled and is not configurable.
2. AUG mapping is only available for SDH framing.
3. s1s0 should be set to 2 for SDH framing.
Table 25 1-Port Channelized OC-48/STM-16 ISE and 4-Port Channelized OC-12/STM-4 ISE Line
Cards Controller Parameters and Default Configuration Values (continued)
Parameter
1