Example
Use the show power inline command to verify the power configuration on the ports, as illustrated below.
Router# show power inline
PowerSupply SlotNum. Maximum Allocated Status
----------- -------- ------- --------- ------
INT-PS 0 120.000 101.500 PS GOOD
Interface Config Phone Powered PowerAllocated
--------- ------ ----- ------- --------------
Fa0/1/0 auto Cisco On 6.300 Watts
Fa0/1/1 auto Cisco On 6.300 Watts
Fa0/1/2 auto Cisco On 6.300 Watts
Fa0/1/3 auto Cisco On 6.300 Watts
Fa0/1/4 auto Cisco On 6.300 Watts
Fa0/1/5 auto Cisco On 6.300 Watts
Fa0/1/6 auto Cisco On 6.300 Watts
Fa0/1/7 auto Cisco On 6.300 Watts
Fa0/3/0 auto Cisco On 6.300 Watts
Fa0/3/1 auto Cisco On 6.300 Watts
Fa0/3/2 auto Cisco On 6.300 Watts
Fa0/3/3 auto Cisco On 6.300 Watts
Fa0/3/4 auto Cisco On 6.300 Watts
Fa0/3/5 auto Cisco On 6.300 Watts
Fa0/3/6 auto IEEE-2 On 7.000 Watts
Fa0/3/7 auto Cisco On 6.300 Watts
Configuring IP Multicast Layer 3 Switching
These sections describe how to configure IP multicast Layer 3 switching:
• Enabling IP Multicast Routing Globally, page 57
• Enabling IP Protocol-Independent Multicast (PIM) on Layer 3 Interfaces, page 59
• Verifying IP Multicast Layer 3 Hardware Switching Summary, page 60
• Verifying the IP Multicast Routing Table, page 61
Enabling IP Multicast Routing Globally
You must enable IP multicast routing globally before you can enable IP multicast Layer 3 switching on
Layer 3 interfaces.
Step 5
end
Example:
Router(config-if)# end
Returns to privileged EXEC mode.
Step 6
show power inline
Example:
Router# show power inline
Displays power configuration on the ports.
Command Purpose