3. Upon power on or restart, the service initializes into the Boot over InfiniBand firmware
menu shown in Figure 6-23. Ensure that option
2 “Well Known boot service” (the default
value) is selected. Then select option s to save the configuration and select x to exit the
InfiniBand firmware menu.
Figure 6-23 InfiniBand HCA Firmware menu
InfiniBand boot driver v3.2.0 build 106
(c)Copyright Topspin Communications, Inc. 2003-2005
Type 'x' to configure boot options
Node GUID: 0005ad0000050724
Waiting for SM to configure ports............................x...........
............................................
[ 0] PXE Boot
Port LID IOC Service Name
[ 1] * - - 201500a0b8261210 [saved service]
[ 2] * * * 20000005ad00ffff [Well known boot service]
ERROR: Bad service name format
[ 3] 1 40 1 201500a0b8261210
[ 4] 1 39 1 201500a0b8261210
[e(x)it, (o)ptions, (s)ave, (r)estore, re(f)resh, (d)efault, d(i)sable]
Select [ 2] s
Please wait while boot configuration data is being saved.
[ 0] PXE Boot
Port LID IOC Service Name
[ 1] * - - 201500a0b8261210 [saved service]
[ 2] * * * 20000005ad00ffff [Well known boot service]
ERROR: Bad service name format
[ 3] 1 40 1 201500a0b8261210
[ 4] 1 39 1 201500a0b8261210
[e(x)it, (o)ptions, (s)ave, (r)estore, re(f)resh, (d)efault, d(i)sable]
Select [4]: x
Connected to: 0x201500a0b8261210 at port: 1 lid 0x0027, ioc: 1
Vendor: IBM
Model : 1814 FAStT
Drive C redirected to the SRP target