Installation guide
A-52
Cisco IGX 8400 Series Installation Guide, Release 9.3.3 and Later Releases
OL-1165-06
Appendix A System Specifications
Cisco Cabinet Dimensions
Cisco Cabinet Dimensions
This section illustrates the space requirements for various system configurations in the Cisco cabinet and
a typical cable management setup. It also contains a table with the height of Cisco WAN switching
components in inches, centimeters, and rack-mount units (RMUs). This can help in the calculation of
height requirements for individual system configurations. The last illustration shows the bracket
installation in the Cisco cabinet (for a BPX 8620 node, in this case). The illustrated components are:
• BPX 8620
• IGX 8410, 8420, and 8430 switches
• Cisco MGX 8220 edge concentrator
The sequence of illustrations in this chapter is as follows:
• Cisco Cabinet
• Cable Management
• Examples of System Configurations
• Table of Component Heights
Table A-52 Standard IGX Cables
Model Description Usage
5608 T1, pigtail to RJ48 CSU to telco demarc
5614 T1/M15-M15 turnover E1 trunk to CSU
5616 T1/M15-M15 –
5680 BNC-DB-15 E1 trunk
5685 T1/M15-M15 turnover, Y-cable E1 trunk redundancy
5630 V.35/M34-F34 Subrate trunk or data circuit
5636E V.35 Y-cable Subrate trunk or data circuit redundancy
5645 EIA/TIA-422/X.21 adapter-DTE IGX is DTE
5646 EIA/TIA-422/X.21 adapter-DCE IGX is DCE
5644 EIA/TIA-422 Y-cable Subrate trunk or data circuit redundancy
5695 X.21/DB-15 Y-cable Subrate trunk or data circuit redundancy
5620 EIA/TIA-232/M25-F25 Control port to control
terminal, StrataView Plus, or external
window device
5621 EIA/TIA-232/M25-M25 special Control or Aux. port to modem
5625 V.35/M15-F25 LDI8 (DCE) to data device
5626E V.35/M15-M25 LDI8 (DTE) to data device
5629 EIA/TIA 232/M15-M15, Y-cable LDI redundancy