Installation guide
A-21
Cisco IGX 8400 Series Installation Guide, Release 9.3.3 and Later Releases
OL-1165-06
Appendix A System Specifications
Peripheral Specifications
Peripheral Specifications
Note EIA/TIA-232 and EIA/TIA-449 existed as recommended standards RS-232 and RS-449 before the
Electronics Industries Association (EIA) and Telecommunications Industry Association (TIA) accepted
them as standards.
Network Management Terminal
StrataView Terminal
A Cisco WAN Manager workstation is required for managing an IGX network. Refer to the
Cisco WAN Manager Installation publication for setup instructions and specifications for the Cisco
Network Management Terminal. The Cisco WAN Manager Installation publication has all the necessary
information for obtaining network alarm, control, and statistics from IGX switch software for
Cisco WAN Manager.
Control Terminal
Table A-1 lists the control terminals requirements.
Table A-1 Control Terminal Requirements
Parameter Requirement
IGX Port Used Control terminal port on the SCM card is used to interface with a
local control terminal
Code Standard 7- or 8-bit ASCII; 1 or 2 stop-bits; even, odd, or no
parity
Interface EIA/TIA-232 DCE
Data Rate All standard asynchronous data rates from 300 to 19200 bps,
independently software-selectable
Supported Terminals VT-100, or equivalent, recommended
Cable Required Straight-through EIA/TIA-232 cable