Installation guide
5-7
Cisco IGX 8400 Series Installation Guide, Release 9.3.3 and Later Releases
OL-1165-06
Chapter 5 Replacing Parts on the IGX
Replacing an AC Power Supply
Replacing an AC Power Supply
This section contains separate descriptions for replacing an AC power supply in IGX 8410,
IGX 8420, and IGX 8430 nodes.
Replacing an AC Power Supply in an IGX 8410 Node
When a power supply has failed, a red FAIL light on the SCM comes on and one or more “okay” LEDs
on the power supply go off. Before replacing a power supply, check if it needs only to be reseated. The
following describes first how to reseat, then how to replace, a supply.
Step 1 Loosen the captive screws and remove the AC power cover plate. See Figure 5-2.
Figure 5-2 Replacing an AC Power Supply
Step 2 Identify the power supply that needs replacement.
Step 3 Grip the hinged handle on the supply, slightly pull out the supply, then reseat it. This resets the supply’s
internal power-monitoring circuit. See Figure 5-3.
Step 4 Check the supply-monitoring circuit on the SCM. First, enter the command resetcd 0 at the control
terminal (this resets the power supply monitor on the SCM). After waiting about 10 seconds or more,
enter the dsppwr command and see if the FAIL indicator for the supply comes on. Note which power
supply has failed.
Cover plate
over power
supplies
Captive
screws (2)
Clamping
rings
Circuit
breakers
AC inputs
P
S
D
P
S
C
P
S
B
PS
A
H8392