Specifications

2-12
Cisco IGX 8400 Series Provisioning Guide, Release 9.3.3 and Later Releases
OL-1166-04
Chapter 2 Cisco IGX 8400 Series Cards
Alarm Relay Module
Figure 2-5 ARI Faceplate
ARM Configuration and Management
Enable alarm display functionality on the ARM with the switch software addalmslot command. The
ARM requires standard management and preventive maintenance tasks.
Making Alarm Relay Output Connections
To set up an ARM after installation, use the following procedure:
Step 1 Log in to the IGX node.
Step 2 Enter the switch software addalmslot slot command to activate alarm reporting from the card.
Step 3 Check the active LED on the front card faceplate.
Step 4 Test alarm output operation by creating an alarm on the node.
Tip Create an alarm by disconnecting a trunk cable from the connector on the back card.
ARI
5120N
ALARM
RELAYS
H8333
DB-37