Specification Guide

© 2016 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 9 of 13
Part Number
SFP Type
Max
Distance
Cable Type
Temp
Range
*
DOM
Support
GLC-BX40-DA-I=
GE
40km
SMF
IND
Yes
GLC-BX80-U-I=
GE
80km
SMF
IND
Yes
GLC-BX80-D-I=
GE
80km
SMF
IND
Yes
GLC-SX-MMD=
GE
550m
MMF
EXT
Yes
GLC-LH-SMD=
GE
550m/10km
MMF/SMF
EXT
Yes
GLC-EX-MMD=
GE
40km
SMF
EXT
Yes
GLC-ZX-MMD=
GE
70km
SMF
EXT
Yes
GLC-BX-D=
GE
10km
SMF
COM
Yes
GLC-BX-U=
GE
10km
SMF
COM
Yes
CWDM-SFP-xxxx= (8 freq)
GE
SMF
COM
Yes
DWDM-SFP-xxxx= (40 freq)
GE
SMF
COM
Yes
SFP-GE-S=
GE
550m
MMF
EXT
Yes
SFP-GE-L=
GE
550m/10km
MMF/SMF
EXT
Yes
SFP-GE-Z=
GE
70km
SMF
EXT
Yes
GLC-SX-MM=
GE
550m
MMF
COM
No
GLC-LH-SM=
GE
550m/10km
MMF/SMF
COM
No
GLC-ZX-SM=
GE
70km
SMF
COM
Yes
GLC-TE=
GE
100m
Copper
EXT
NA
GLC-T=
GE
100m
Copper
COM
NA
Note: For DOM support and for first software release supporting SFP, refer to
http://www.cisco.com/en/US/products/hw/modules/ps5455/products_device_support_tables_list.html.
*
If non industrial (i.e., EXT, COM) SFPs are used the switch operating temperature must be derated.
Table 6. Compliance Specifications
Description
Specification
Standard safety certifications
UL 60950-1
CSA C22.2 No. 60950-1
TUV/GS to EN 60950-1
CB to IEC 60950-1 with all country deviations
NOM
Mechanical stability
IEC 60628-2-27 Shock 20g (operational), 30g (nonoperational)
Electromagnetic Emissions
FCC Part 15 Class A
EN 55022
CISPR 22
CISPR11
VCCI Class A
AS/NZS 3548 Class A
CNS 13438 Class A
KN 22 Class A
Electromagnetic Immunity
EN 55024
AS/NZS CISPR 24
KN 24
IEC/EN 61000-4-2 (Electro Static Discharge)
IEC/EN 61000-4-3 (Radiated Immunity)
IEC/EN 61000-4-4 (Fast Transients)
IEC/EN 61000-4-5 (Surge)
IEC/EN 61000-4-6 (Conducted Immunity)
IEC/EN 61000-4-8 (Power Frequency Magnetic Field Immunity)