Specification Guide

© 2016 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 10 of 13
Description
Specification
IEC/EN 61000-4-9 (Pulse Magnetic Field Immunity)
IEC/EN 61000-4-10 (Oscillatory Magnetic Field Immunity)
IEC/EN 61000-4-11 (AC power Voltage Immunity)
IEC/EN 61000-4-16 (Low Frequency Conducted CM Disturbances)
IEC/EN 61000-4-17 (Ripple on DC Input Power)
IEC/EN 61000-4-18 (Damped Oscillatory Wave)
IEC/EN 61000-4-29 (Voltage Dips Immunity, DC power)
IEEE C37.90 (Surge)
IEEE C37.90.1 (Fast Transients)
IEEE C37.90.2 (Radiated Immunity)
IEEE C37.90.3 (Electro Static Discharge)
Industry specifications
EN 61131-2 Programmable Controllers (EMC/EMI, environmental, mechanical)
IEEE 1613 Power Station and Substation Networking Devices
IEC 61850-3 Power Station and Substation Communication Networks and Systems
EN 61326-1 Electrical Equipment for Measurement, Control and Laboratory Use - EMC
EN 61000-6-1 Immunity for Light Industrial Environments
EN 61000-6-2 Immunity for Industrial Environments
EN 61000-6-4 Emissions for Industrial Environments
TS 61000-6-5 EMC Immunity for Power Station and Substation
EN 50155 Railway, Electronic Equipment on Rolling Stock (EMI/EMC, environmental, mechanical)
EN 50121-3-2 Railway, Electromagnetic Compatibility on Rolling Stock
EN 50121-4 Railway, Emission and Immunity of Signaling and Telecommunications Apparatus
EN 60945 Maritime Navigation and Radio-communication Equipment and Systems
IEC 60533 Shipboard Electrical and Electronic Installation EMC
Marine Type Approval (BV, DNV, Korean Register, Lloyd Register)
NEMA TS-2 (EMC, environmental, mechanical)
ABB Industrial IT certification
ODVA Industrial EtherNet/IP support
PROFINETv2 support
Directive 2011/65/EU RoHS
IP20
Hazardous locations
UL/CSA 60079-0, -15 (Class 1, Div 2 A-D) (requires cabinet enclosure)
EN 60079-0, -15 ATEX Certification (Class 1, Zone 2 A-D) (requires cabinet enclosure)
IEC 60079-0, -15 (Test report only) (requires cabinet enclosure)
UL 508
CSA C22.2 No. 142
Compliance Marking
UL/CSA
CE (Europe)
C-Tick (Australia/New Zealand)
KCC (Korea)
ANATEL (Brazil)
China RoHS
Operating Temperature
-40 C to +70 C (vented enclosure operating)
-40 C to +60 C (sealed enclosure operating)
-34 C to +75 C (fan or blower-equipped enclosure operating)
-40 C to +85 C (IEC Environmental Type Testing, 16 hours)
Operational altitude: Up to 13,000 ft
Storage Temperature
-40 C to +85 C (storage temperature)
Storage altitude: Up to 15,000 ft
Humidity
Relative humidity: 5% to 95% non-condensing
Telco
Common Language Equipment Identifier (CLEI) code
Warranty
Five year limited warranty