Specifications
17-45
System Management Software Configuration Guide for Cisco IE 2000U and Connected Grid Switches
Chapter 17 Configuring Ethernet OAM, CFM, and E-LMI
Configuring Ethernet OAM
Step 5
ethernet oam link-monitor frame {threshold
{high {high-frames | none} | low
{low-frames}} | window milliseconds}
(Optional) Configure high and low thresholds for
error frames that trigger an error-frame link event.
• Enter threshold high high-frames to set a high
threshold in number of frames. The range is 1 to
65535. You must enter a high threshold.
• Enter threshold high none to disable the high
threshold.
• Enter threshold low low-frames to set a low
threshold in number of frames. The range is 0 to
65535. The default is 1.
• Enter window milliseconds to set the a window
and period of time during which error frames are
counted. The range is 10 to 600 and represents
the number of milliseconds in a multiple of 100.
The default is 100.
Step 6
ethernet oam link-monitor frame-period
{threshold {high {high-frames | none} | low
{low-frames}} | window frames}
(Optional) Configure high and low thresholds for the
error-frame period that triggers an
error-frame-period link event.
• Enter threshold high high-frames to set a high
threshold in number of frames. The range is 1 to
65535. You must enter a high threshold.
• Enter threshold high none to disable the high
threshold.
• Enter threshold low low-frames to set a low
threshold in number of frames. The range is 0 to
65535. The default is 1.
• Enter window frames to set the a polling
window size in number of frames. The range is
1 to 65535; each value is a multiple of 10000
frames. The default is 1000.
Step 7
ethernet oam link-monitor frame-seconds
{threshold {high {high-seconds | none} | low
{low-seconds}} | window milliseconds}
(Optional) Configure frame-seconds high and low
thresholds for triggering an error-frame-seconds link
event.
• Enter threshold high high-seconds to set a high
threshold in number of seconds. The range is 1
to 900. You must enter a high threshold.
• Enter threshold high none to disable the high
threshold.
• Enter threshold low low-frames to set a low
threshold in number of frames. The range is 1 to
900. The default is 1.
• Enter window frames to set the a polling
window size in number of frames. The range is
100 to 9000; each value is a multiple of 100
milliseconds. The default is 1000.
Command Purpose