Step 5
ethernet oam link-monitor frame {threshold
{high {high-frames | none} | low
{low-frames}} | window milliseconds}
Note Repeat this step to configure both high
and low thresholds.
(Optional) Configure high and low thresholds for
error frames that trigger an error-frame link event.
• Enter threshold high high-frames to set a high
threshold in number of frames. The range is 1 to
65535. The default is none.
• Enter threshold high none to disable the high
threshold if it was set. This is the default.
• Enter threshold low low-frames to set a low
threshold in number of frames. The range is 0 to
65535. The default is 1.
• Enter window milliseconds to set the a window
and period of time during which error frames are
counted. The range is 10 to 600 and represents
the number of milliseconds in multiples of 100.
The default is 100.
Step 6
ethernet oam link-monitor frame-period
{threshold {high {high-frames | none} | low
{low-frames}} | window frames}
Note Repeat this step to configure both high
and low thresholds.
(Optional) Configure high and low thresholds for the
error-frame period that triggers an
error-frame-period link event.
• Enter threshold high high-frames to set a high
threshold in number of frames. The range is 1 to
65535. The default is none.
• Enter threshold high none to disable the high
threshold if it was set. This is the default.
• Enter threshold low low-frames to set a low
threshold in number of frames. The range is 0 to
65535. The default is 1.
• Enter window frames to set the a polling
window size in number of frames. The range is
1 to 65535; each value is a multiple of 10000
frames. The default is 1000.
Command Purpose