System Management Software Configuration Guide for Cisco IE 2000U and Connected Grid Switches
Chapter 12 Configuring RMON
Configuring RMON
DETAILED STEPS
Command Purpose
Step 1
configure terminal Enter global configuration mode.
Step 2
rmon alarm number variable interval {absolute |
delta} rising-threshold value [event-number]
falling-threshold value [event-number]
[owner string]
Set an alarm on a MIB object.
For number, specify the alarm number.
The range is 1 to 65535.
For variable, specify the MIB object to
monitor.
For interval, specify the time in seconds
the alarm monitors the MIB variable. The
range is 1 to 4294967295 seconds.
Specify the absolute keyword to test
each MIB variable directly. Specify the
delta keyword to test the change between
samples of a MIB variable.
For value, specify a number at which the
alarm is triggered and one for when the
alarm is reset. The range for the rising
threshold and falling threshold values is
-2147483648 to 2147483647.
(Optional) For event-number, specify the
event number to trigger when the rising
or falling threshold exceeds its limit.
(Optional) For owner string, specify the
owner of the alarm.
Step 3
rmon event number [description string] [log] [owner
string] [trap community]
Add an event in the RMON event table that is
associated with an RMON event number.
For number, assign an event number. The
range is 1 to 65535.
(Optional) For description string,
specify a description of the event.
(Optional) Use the log keyword to
generate an RMON log entry when the
event is triggered.
(Optional) For owner string, specify the
owner of this event.
(Optional) For trap community, enter the
SNMP community string used for this
trap.
Step 4
end Return to privileged EXEC mode.
Step 5
show running-config Verify your entries.
Step 6
copy running-config startup-config (Optional) Save your entries in the
configuration file.