Spec Sheet
© 2012 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 4 of 7
Description Specification
●
Russia certification
●
Brazil certification
●
IEC/EN/EN61000-4-2 (Electro Static Discharge), 15kV Air/8kV Contact
●
IEC/EN 61000-4-3 (Radiated Immunity, 10 and 20V/m)
●
IEC/EN 61000-4-4 (Fast Transients - 4kV power line, 4kV data line
●
IEC/EN 61000-4-5 (Surge 2 kV/1 kV)
●
IEC/EN 61000-4-6 (Conducted Immunity, 10V/emf)
●
IEC/EN 61000-4-8 (Power Frequency Magnetic Field Immunity)
●
IEC/EN 61000-4-9 (Pulse Magnetic Field Immunity)
●
IEC/EN 61000-4-10 (Oscillatory Magnetic Field Immunity)
●
IEC/EN 61000-4-11 (AC power Voltage Immunity)
●
IEC/EN 61000-4-29 (Voltage Dips Immunity)
●
IEC/EN 61000-6-1 (Immunity for Light Industrial Environments)
●
IEC/EN 61000-6-4 Class A
●
EN 61326
Shock and Vibration
●
IEC 60068-2-27 (Operational Shock: 30G 11ms, half sine)
●
IEC 60068-2-27 (Non-Operational Shock 55-70G, trapezoidal)
●
IEC 60068-2-6, IEC 60068-2-64, EN 61373 (Operational Vibration)
●
IEC 60068-2-6, IEC 60068-2-64, EN 61373 (Non-operational Vibration)
Industry Standards
●
UL 508
●
CSA C22.2 No. 142
●
EN 61131-2 (Programmable Controllers)
●
Protective Coating
●
Substation (IEEE 1613, IEC 61850-3) KEMA post FCS
●
Lloyd’s Register Type Approval - ENV2 or ENV3
●
British, German Lloyds
●
Marine (LR, BV, GL, DnV, Rina ABS, KR)
●
RA 156-165 Mhz 24 dBuV/M - Class A is 50 dBuV/M - Marine Band
●
Railway EN 50155, EN50121-3-2, EN50121-4 (EMI, EMC, Mechanical)
●
NEMA TS-2
●
ABB Industrial IT Certification
●
IP30
●
ODVA Industrial EtherNet/IP support in15.0(1)EY1
●
PROFINETv2 support in 15.0(1)EY2
Corrosive Testing
*
●
ISO-12944-6
●
IEC-60068-2-60
Humidity
●
IEC 60068-52-2 (Salt Fog Mist, Test Kb) Marine environments
●
IEC 60068 -2-3
●
IEC 60068-2-30
●
Relative Humidity: 5% to 95% Non-condensing
Operating Temperature
●
-40C to +70C (Vented Enclosure Operating)
●
-40C to +60C (Sealed Enclosure Operating)
●
-34C to +75C (Fan or Blower equipped Enclosure Operating)
●
Operational Altitude: Up to 15,000 ft
Storage Temperature
●
-40C to +85C (Storage Temperature)
●
IEC 60068-2-14
●
Storage Altitude: Up to 15,000 ft
MTBF
●
Mean time between failure: 374,052 hrs (42.7 yrs)
Warranty
●
One year limited warranty