22 QPSK (Release A63) Software Upgrade and Installation Instructions 4002804 Rev C
What to Look for in the signonCount Data, Continued
Fix
Mode
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
FIX Mode—This field reveals whether the signonCount utility is
configured to correct DHCT sign-on problems (Fix Mode On) or
whether the utility is running in information-only mode (Fix
Mode Off).
Note: By default, the utility runs in Fix Mode Off.
Important: Do not change modes unless you have been
instructed to do so by Cisco Services engineers.
Verified
Rcvd Sent
57 55
73 73
62 59
66 61
64 62
74 64
94 95
70 66
67 65
78 72
Verified Rcvd—The QPSK modulator reports the number of
DHCTs that have made sign-on requests.
Verified Sent—The DNCS has responded to this number of
DHCTs.
DAVIC
Made
18
26
8
15
20
16
37
17
19
22
DAVIC Made—The QPSK modulator reports the number of
DHCTs that have connected to the QPSK modulator and are
waiting for UN-Config information.
UN-Config
Rcvd Sent
0 0
0 0
4 4
3 3
6 6
4 4
8 8
3 3
5 5
2 2
UN-Config Rcvd—This number of DHCTs is requesting a UN-
Config message from the DNCS.
The UN-Config message contains information, like an IP
address, that allows DHCTs to sign on to the network.
UN-Config Sent—The DNCS has sent this number of UN-
Config messages to DHCTs, allowing the DHCTs to sign on to
the network.
At this point, the DHCTs are physically in two-way mode and
have completed the sign-on process