Datasheet

© 2006 Cisco Systems, Inc. All rights reserved.
Important notices, privacy statements, and trademarks of Cisco Systems, Inc. can be found on cisco.com.
Page 5 of 8
Security
Power-on password
Privileged access password to server setup
Unattended boot mode allows keyboard to be locked to all entries except the password
Selectable boot sequence
Industry Standard Compliance
Advanced configuration and power interface (ACPI) 2.0 Compliant
PCI 2.3 Compliant
PCI-X specification v1.0a
International Organization for Standardization (ISO) 9241, Part 3
MPS 1.4
Microsoft Logo certifications
Equipment Approvals and Safety
Federal Communication Commission (FCC)—Verified to comply with Part 15 of the FCC Rules, Class A
Canada Information Collection and Evaluation Standard (ICES)-003, issue 3, Class A
Underwriters Laboratories 1950
CSA C22.2 No. 950
NOM-018
Expansion Options
PCI-X non-hot-plug 133MHz/64-bit slots 2 (Full-length, full-height—usable for Cisco Unity voice cards)
PCI-X non-hot-plug 100MHz/64-bit slots 2 (Low-profile, not usable for Cisco Unity voice cards)
Power
Steady State Output Power 625W
Auto-ranging AC mains input Yes
Power factor correction (PFC) Yes
Maximum hot-swap power supplies 2
Hot-swap power supplies installed 2
Mains input frequency range 47-63Hz
Operational input voltage ranges 90-137 VAC minimum
180-265 VAC maximum
Input current (per power supply) 10.0A (100-127 VAC nominal)
5.0A (200-240 VAC nominal)
Environmental
Air temperature at 0 to 3000 ft (0 to 914 m) 50.0 to 95.0°F (10 to 35°C)
Air temperature at 3000 to 7000 ft (914 to 2133 m) 50.0 to 90°F (10 to 32°C)
Relative humidity 10 to 80 percent
British Thermal Unit (BTU) rating
(maximum configuration)
2840 BTU per hour
Sound emissions maximum 6.6 BELS
Dimensions
Form factor Rack-mount 2U
Rack-mounting Included for standard third-party rack