System information
Appendix C 
Module Parameter Descriptions 
272  4025561
Rev
A
Optical Switch Control Parameters 
Parameter Function  Possible Values Default 
Mode  Selects Cross, Bar, or Auto mode  Cross (0) 
Bar (1) 
Auto (2) 
Auto (2) 
WaveLen  Selects wavelength of input for both 
inputs 
1310 nm (0) 
1550 nm (1) 
1550 nm (1)
NomPin3  Nominal input power at Port 3 in dBm  -8.0 to 23.0 dBm, 
0.1 dB steps 
21.0 dBm 
NomPin4  Nominal input power at Port 4 in dBm  -8.0 to 23.0 dBm, 
0.1 dB steps 
21.0 dBm 
Delta  Value relative to nominal below which 
the input must fall to switch (Auto mode)
1 to 10 dB, in 0.1 
dB steps 
2.0 dB 
HystAmpl  Hysteresis amplitude: the value above 
which the input must rise to start hyst 
timer to restore original switch position 
(only if Revert is Auto) 
0.5 to 9.5 dB in 0.1 
dB steps 
1.0 dB 
HystTime  Hysteresis time: length of time primary 
power is above restore threshold before 
switch to primary (only if Revert is Auto) 
integer in seconds 
from 0 to 600 
60 sec 
Revert  Allows switch to revert to primary after 
power is restored; in Manual, switch stays 
in backup position 
Manual (0) 
Auto (1) 
Auto (1) 
PrimInp  Selects primary input (Auto mode)  Port_3 (0) 
Port_4 (1) 
Port_4 (1) 
DfltSw  Selects the normal switch position (Auto 
mode) 
Cross (0) 
Bar (1) 
Bar (1) 
Optical Switch Manufacturing Data Parameter Examples 
Manufacturing Data  Typical Values 
Set in Manufacturing 
(example value shown) 
Module Name  Optical Switch FTTP 
Module Type  4011 
Serial # [1]  ABCDEFG 
X 
Date Code [1]  B01 
X 