Data Sheet
GainMaker
®
- High Gain Dual - 5-40/52-1002 MHz
3
Specifications
General Station Performance Units Forward Reverse Notes
Pass Band MHz 52-1002 5-40
Amplifier Type --- GaAs FET PP
Frequency Response dB
±0.5 ±0.4
Auto Slope and Gain Range dB
±5.5
n/a
Return Loss dB 16 16 7
Max AC Through Current (continuous) Amps 15 -
Max AC Through Current (surge) Amps 25 -
Hum Modulation @ 12 A
(over specified frequency range)
dB 70 (52-870 MHz)
60 (870-1002 MHz)
60 (5-10 MHz)
70 (11-40 MHz)
Hum Modulation @ 15 A
(over specified frequency range)
dB 65 (52-870 MHz)
60 (870-1002 MHz)
60 (5-10 MHz)
65 (11-40 MHz)
Test Points (± 0.5 dB)
dB -20 -20
Reference Output Level @… 1002 MHz
870 MHz
dBmV
49.5
47.5
35 (@40 MHz)
750 MHz 45.7
650 MHz 44.0
550 MHz 42.5
55 MHz 35.0 35 (@ 5 MHz)
Reference Output Tilt (55-1002 MHz) dB 14.5 - 1
Forward Station Performance
Units
Auto/Thermal
with 10.5 dB I/S EQ
Notes
Operational Gain (minimum) dB 43 2
Internal Tilt (± 0.5 dB)
dB 15.5 3
Noise Figure @ 54 MHz dB 8.5 2
Noise Figure @ 1 GHz dB 8.0 2
78 NTSC Channels (CW) with digital
4
Composite Triple Beat dB 80 9
Cross Modulation dB 72 5,9
Composite Second Order (high side) dB 70 9
94 NTSC Channels (CW) with digital
8
Composite Triple Beat dB 75 9
Cross Modulation dB 67 5,9
Composite Second Order (high side) dB 67 9
Reverse Station Performance Units Notes
Operational Gain (minimum) dB 19.5 6,7
Internal Tilt (± 0.5 dB)
dB 0 3
Noise Figure dB 12 6,7
6 NTSC Channels (CW)
Composite Triple Beat dB 92 9
Cross Modulation dB 80 5,9
Composite Second Order (high side) dB 82 9
Unless otherwise noted, specifications reflect typical performance and are referenced to 68°F (20°C). Specifications are based
upon measurements made in accordance with SCTE/ANSI standards (where applicable), using standard frequency assignments.