Release Notes for Cisco IOS Release 12.1E on the Catalyst 6500 and Cisco 7600 Supervisor Engine and MSFC
OL-2310-11
Caveats
The ciscoFlashDeviceInitTime CISCO-FLASH-MIB object does not return the correct device
initialization (insertion or removal) time stamp for the Flash devices on a redundant supervisor
engine. Users of applications that depend on ciscoFlashDeviceInitTime should take care not to
remove a redundant supervisor engine or a PCMCIA card from slave-slot0 when the applications are
performing Flash file operations. This problem is resolved in Release 12.1(11b)E. (CSCdp98597)
A traceback message displays when you exit the switch console. This message is harmless and can
be safely ignored. This problem is resolved in Release 12.1(8a)E. (CSCdp35517)
Resolved Caveats in Release 12.1(7a)E6
An error can occur with management protocol processing. Please use the following URL for further
information:
http://www.cisco.com/cgi-bin/bugtool/onebug.pl?bugid=CSCdw65903
This problem is resolved in Release 12.1(7a)E6. (CSCdw65903)
Resolved Caveats in Release 12.1(7a)E1
After erasing the NVRAM and rebooting the system, the line protocol might not come up on some
interfaces. This problem is resolved in Release 12.1(7a)E1. (CSCdu09356)
Resolved Caveats in Release 12.1(7)E
The crypto map interface command causes a reload. This command is disabled in Release 12.1(7)E.
(CSCdu03017)
You cannot configure the MTU size on VLAN interfaces. For Supervisor Engine 2, this problem is
resolved in Release 12.1(8a)E. For Supervisor Engine 1, this problem is resolved in
Release 12.1(7)E. (CSCdr62024, CSCdr54103)
FlexWAN Module Caveats
Open FlexWAN Module Caveats in Release 12.1(7a)E6, page 304
Resolved FlexWAN Module Caveats in Release 12.1(7a)E6, page 305
Resolved FlexWAN Module Caveats in Release 12.1(7a)E1, page 305
Resolved FlexWAN Module Caveats in Release 12.1(7)E, page 305
Open FlexWAN Module Caveats in Release 12.1(7a)E6
Flows between an Ethernet interface configured with an HSRP standby IP address and a WAN
interface might not be Layer 3 switched. This problem is resolved in Release 12.1(8a)E.
(CSCds66364)
FlexWAN module crashinfo files do not propagate to the MSFC bootflash device.
Workaround: Display the FlexWAN module crashinfo filename with the dir
cwanslot_number/port_adapter_number-bootflash: command. You can copy a FlexWAN module
crashinfo file with the copy cwanslot_number/port_adapter_number-bootflash: command. This
problem is resolved in Release 12.1(14)E. (CSCdr71603)
To use the interfaces on the FlexWAN module, you must enable IP routing on the MSFC.
(CSCdp34896)