Datasheet
235
Release Notes for Cisco IOS Release 12.1E on the Catalyst 6500 and Cisco 7600 Supervisor Engine and MSFC
OL-2310-11
Caveats
Resolved General Caveats in Release 12.1(13)E11
• The show mac-address-table command might incorrectly display “<drop>” instead of “flood to
vlan” for a MAC address. This is a cosmetic error. This problem is resolved in Release 12.1(13)E11.
(CSCdz83191)
• Incorrect traffic loss occurs if you enter a shutdown command and then a no shutdown command
on a Layer 3 VLAN interface that has HSRP configured. This problem is resolved in
Release 12.1(13)E11. (CSCec26522)
• The WS-X6348-RJ-45, WS-X6248-RJ-45, WS-X6248-TEL, and WS-X6348-RJ-21V modules
might randomly reset. This problem is resolved in Release 12.1(13)E11. (CSCeb35612)
Resolved General Caveats in Release 12.1(13)E10
• The scheduler allocate command process-time default value is too small (200 microseconds,
changed to 800 microseconds with this fix). The no scheduler allocate command does not return
the configuration to default values. These problems are resolved in Release 12.1(13)E10.
(CSCeb75803)
• There might be OSPF neighbor drops and HSRP flaps when QoS is enabled on a Supervisor
Engine 1 and MSFC2. This problem is resolved in Release 12.1(13)E10. (CSCeb55271)
• Routing protocols do not work on EtherChannels that are reconfigured from Layer 2 to Layer 3. This
problem is resolved in Release 12.1(13)E10. (CSCeb60132)
• An IEEE 802.Q trunking Gigabit EtherChannel formed with interfaces on different DFC-equipped
switching modules might drop some traffic that is Layer 3 switched in hardware or that is routed in
software. This problem is resolved in Release 12.1(13)E10. (CSCeb05464)
• With the ip pim spt-threshold infinity command configured, if there is an (S,G) entry without its
SPT bit set, the (*,G) entry might not be partially Layer 3 switched, which might cause routers not
to forward packets on the (S,G) entry. This problem is resolved in Release 12.1(13)E10.
(CSCdy73168)
• When a Cisco IOS server load balancing (Cisco IOS SLB) virtual server is configured for RADIUS
load balancing with the msid-cisco keyword, then Accounting-Start RADIUS requests from a Home
Agent may not be load-balanced to the same real server as the Access-Request. This problem is
resolved in Release 12.1(13)E10. (CSCeb00351)
• On WS-X6548-GE-TX and WS-X6548V-GE-TX modules, CEF-switched Ethernet egress packets
that are less than 64-bytes long are not padded correctly. This problem is resolved in
Release 12.1(13)E10. (CSCeb47640)
• After a fatal error, auto-reload fails. This problem is resolved in Release 12.1(13)E10.
(CSCdy38915)
• Memory is not released correctly when a port transitions between up and down. This problem is
resolved in Release 12.1(13)E10. (CSCeb82767, CSCdy57025)
• A redundant supervisor engine might not reload if you enter the reload command on the redundant
supervisor engine's console or physically remove and reinsert the redundant supervisor engine. This
problem is resolved in Release 12.1(13)E10. (CSCea66858)
• When not configured with a redundant power supply, continuous reloads might happen if the output
from the single power supply is momentarily unstable, which causes this message to be displayed:
"%C6KPWR-2-INSUFFICIENTPOWER: Powering down all linecards as there is not enough power
to operate all critical cards"
This problem is resolved in Release 12.1(13)E10. (CSCea82777)