Datasheet

111
Release Notes for Cisco IOS Release 12.1E on the Catalyst 6500 and Cisco 7600 Supervisor Engine and MSFC
OL-2310-11
Limitations and Restrictions
These modules do not support Inter-Switch Link (ISL) VLAN trunking:
WS-X6502-10GE
WS-X6548-GE-TX
WS-X6148-GE-TX
The link state messages (“LINK-3-UPDOWN” and “LINEPROTO-5-UPDOWN”) are disabled by
default. With Release 12.1(19)E1a and later releases, enter the logging event link status command
on each interface where you want the messages enabled.
In Release 12.1(19)E and later releases, you cannot disable IP routing. (CSCdu05871)
IPsec in software on the MSFC is supported only for administrative connections to Catalyst 6500
series switches and Cisco 7600 series routers.
SPAN and RSPAN destination ports and VACL capture ports can receive VACL-redirected traffic.
(CSCea57673)
If you have a network device in your network with MAC address reduction enabled, you should also
enable MAC address reduction on all other Layer-2 connected network devices to avoid undesirable
root bridge election and spanning tree topology issues.
When MAC address reduction is enabled, the root bridge priority becomes a multiple of 4096 plus
the VLAN ID. With MAC address reduction enabled, a switch bridge ID (used by the spanning-tree
algorithm to determine the identity of the root bridge, the lowest being preferred) can only be
specified as a multiple of 4096. Only the following values are possible: 0, 4096, 8192, 12288, 16384,
20480, 24576, 28672, 32768, 36864, 40960, 45056, 49152, 53248, 57344, and 61440.
If another bridge in the same spanning-tree domain does not run the MAC address reduction feature,
it could win root bridge ownership because of the finer granularity in the selection of its bridge ID.
Enter the copy running-config startup-config command and the redundancy reload peer
command to synchronize SNMP ifIndexes when RPR+ redundancy and SNMP ifIndex persistence
are configured when all modules are online after any system boot or when you insert a module while
the system is running. (CSCdy16763)
RPR+ redundancy automatic startup configuration synchronization supports only the
nvram:startup-config file. With RPR+ redundancy configured, if you enter a boot config command
that does not specify nvram:startup-config as the startup configuration file, you must manually copy
the startup configuration file to the redundant supervisor engine’s device specified in the boot config
command. (CSCdx25320)
RPR+ redundancy does not support configuration entered in VLAN database mode. Use global
configuration mode with RPR+ redundancy.
The following Supervisor Engine 1 software images exceed the 16 MB Supervisor Engine 1
bootflash size:
c6sup12-jk2o3sv-mz
c6sup12-pk2o3sv-mz
c6sup12-jk2sv-mz
c6sup12-jo3sv-mz
c6sup12-jsv-mz
c6sup11-jsv-mz
c6sup11-jk2sv-mz