Specifications

3-11
Cisco Unified Communications Manager Managed Services Guide, Release 8.0(1)
OL-20105-01
Chapter 3 Managing and Monitoring the Health of Cisco Unified Communications Manager Systems
Available Supported MIBs
* HOST-RESOURCES-MIB and possibly other MIBS fail to function or respond
when this service is stopped.
** Only in Cisco Unified CM Release 5.1(3) and Release 6.1(1) and later releases.
***All of the listed processes may not be running as it is a function of the particular
server model or what the service deems appropriate.
****There is more than one process by this name; second argument is relevant for
distinction.
*****Feature Services are not activated by default.
Available Supported MIBs
The following MIBs can be reviewed and used for monitoring system health:
Cisco MIBs (Chapter 7, “Cisco Management Information Base”)
CISCO-CCM-MIB, page 7-1
CISCO-CCM-CAPABILITY, page 7-143
CISCO-CDP-MIB, page 7-149
CISCO-SYSLOG-MIB, page 7-166
CISCO-SYSLOG-EXT-MIB, page 7-174
Industry-Standard MIBs (Chapter 8, “Industry-Standard Management Information Base”)
SYSAPPL-MIB, page 8-1
HOST-RESOURCES-MIB, page 8-73
RFC1213-MIB (MIB-II), page 8-28
IF-MIB, page 8-106
IP Sec Manager ipsec
_mgr
Auto-restarts according to ‘init’ rules (10 if
instantaneous failure, otherwise higher).
SysLog Test Cases For Cisco Unified CM
MGCPGateway
LostComm
Natively supported alarm—GUI Serviceability/Alarm/Catalog, CallManager,
MGCPGatewayLostComm/Find
SDLLinkOOS Natively supported alarm—GUI Serviceability/Alarm/Catalog, CallManager, SDLLinkOOS/Find”
SNMP Trap Test Cases
ccmGatewayFailed
Event
CCM-MIB::ccmGatewayFailed
iBMPSG
PowerSupplyEvent
IBM-SYSTEM-POWER-MIB; pull cord on IBM MCS-7835 & MCS-7845 servers with redundant
power supply to invoke.
Table 3-1 Critical Services to Monitor
Service
Stop | Start|
Restart Instruction
Process
Name
Auto
Restart Description