Specifications

3-79
Cisco Wide Area Application Services Command Reference
OL-11817-01
Chapter 3 CLI Commands
show alarms
The three levels of alarms in WAAS software are as follows:
Critical—Alarms that affect the existing traffic through the WAE, and are considered fatal (the WAE
cannot recover and continue to process traffic).
Major—Alarms which indicate a major service (for example, the cache service) has been damaged
or lost. Urgent action is necessary to restore this service. However, other node components are fully
functional and the existing service should be minimally impacted.
Minor—Alarms which indicate that a condition that will not affect a service has occurred, but that
corrective action is required to prevent a serious fault from occurring.
You can configure alarms using the snmp-server enable traps alarms global configuration command.
Use the show alarms critical EXEC command to display the current critical alarms being generated by
WAAS software applications. Use the show alarms critical detail EXEC command to display additional
details for each of the critical alarms being generated. Use the show alarms critical detail support
EXEC command to display an explanation about the condition that triggered the alarm and how you can
find out the cause of the problem. Similarly, you can use the show alarms major and show alarms
minor EXEC commands to display the details of major and minor alarms.
Use the show alarms history EXEC command to display a history of alarms that have been raised and
cleared by WAAS software on the WAAS device since the last software reload. The WAAS software
retains the last 100 alarm raise and clear events only.
Use the show alarms status EXEC command to display the status of current alarms, and the WAAS
device’s alarm overload status and alarm overload configuration.
Examples Table 3-3 describes the fields shown in the show alarms history display.
Table 3-4 describes the fields shown in the show alarms status display.
Ta b l e 3-3 Field Descriptions for the show alarms history Command
Field Description
Op Operation status of the alarm. Values are R–Raised or C–Cleared.
Sev Severity of the alarm. Values are Cr–Critical, Ma–Major, or Mi–Minor.
Alarm ID Type of event that caused the alarm. For example: wafs_edge_down,
wafs_core_down.
Module/Submodule Software module affected. For example: wafs
Instance Object that this alarm event is associated with. For example, for an alarm event
with the Alarm ID disk_failed, the instance would be the name of the disk that
failed. The Instance field does not have pre-defined values and is application
specific.
Ta b l e 3-4 Field Descriptions for the show alarms status Command
Field Description
Critical Alarms Number of critical alarms.
Major Alarms Number of major alarms.
Minor Alarms Number of minor alarms.
Overall Alarm Status Aggregate status of alarms.