Specifications
3-78
Cisco Wide Area Application Services Command Reference
OL-11817-01
Chapter 3 CLI Commands
show alarms
show alarms
To display information on various types of alarms, their status, and history on a WAAS device, use the
show alarms EXEC command.
show alarms [critical [detail [support]] | detail [support] | history [start_num [end_num [detail
[support]]] | critical [start_num [end_num [detail [support]]]] | detail [support] | major
[start_num [end_num [detail [support]]]] | minor [start_num [end_num [detail [support]]]]]
|
detail [support] | major [detail [support]] | minor [detail [support]] | status]
Syntax Description
Defaults No default behavior or values.
Command Modes EXEC
Device Modes application-accelerator
central-manager
Usage Guidelines The Node Health Manager in the WAAS software enables WAAS applications to raise alarms to draw
attention in error/significant conditions. The Node Health Manager, which is the data repository for such
alarms, aggregates the health and alarm information for the applications, services, and resources (for
example, disk drives) that are being monitored on the WAAS device. For example, this feature gives you
a mechanism to determine if a WAE is receiving overwhelming number of alarms. These alarms are
referred to as “WAAS software alarms.”
WAAS software uses SNMP to report error conditions by generating SNMP traps. The following WAAS
applications can generate a WAAS software alarm:
• Node Health Manager (Alarm overload condition)
• System Monitor (sysmon) for disk failures
critical (Optional) Displays critical alarm information.
detail (Optional) Displays detailed information for each alarm.
support (Optional) Displays additional information about each alarm.
history (Optional) Displays information about the history of various alarms.
start_num (Optional) Alarm number that appears first in the alarm history.
end_num (Optional) Alarm number that appears last in the alarm history.
major (Optional) Displays information about major alarms.
minor (Optional) Displays information about minor alarms.
status (Optional) Displays the status of various alarms and alarm overload
settings.