Specifications

D14330.06 ADMINISTRATOR GUIDE TANDBERG E20July 2009
32
Whats in this Guide? Introduction Getting Started Using E20 The Settings Advanced settings
Advanced Settings
method. For TLS connections a SIP CA-list can be uploaded using
the web interface. If no such CA-list is available on the system then
anonymous Diffie Hellman will be used.
Auto:A provisioning solution based on HTTP bootstrapping. See
“HTTP Bootstrapping” on page 32.
Mailbox
Not used in this version.
MultiWay conference
Name of the MultiWay conference.
Outbound: Off
Not used in this version
Proxy 1
Address: The Proxy Address is the manually configured address
for the outbound proxy. It is possible to use a fully qualified domain
name, or an IP address. The default port is 5060 for TCP and UDP
but another can be provided.
Discovery: When Manual is selected, the manually configured
SIP Proxy address will be used. When Auto is selected, the SIP
Proxy address is obtained using Dynamic Host Configuration
Protocol (DHCP).
Proxy 2–4
Identical to Proxy 1.
TLS verify
For TLS connections a CA-list can be uploaded from the web
interface.
On: Set to On to verify TLS connections. Only TLS connections to
servers, whom x.509 certificate is validated against the CA-list, will
be allowed.
Off: Set to Off to allow TLS connections without verifying them.
The TLS connections are allowed to be set up without verifying
the x.509 certificate received from the server against the local
CA-list. This should typically be selected if no SIP CA-list has been
uploaded.
Type
Enables SIP extensions and special behaviour for a vendor or provider.
Standard: Should be used when registering to standard SIP proxy
like OpenSer.
Nortel: Must be used when registering to a Nortel MCS 5100 or
MCS 5200 PBX.
Microsoft: Must be used when registering to a Microsoft LCS or
OCS server.
Cisco: Must be used when registering to a Cisco CallManager
version 5 or later.
Alcatel: Must be used when registering to a Alcatel-Lucent
OmniPCX Enterprise R7 or later.
Siemens: Must be used when registering to a Siemens HiPath
8000.
Broadsoft: Must be used when registering to a Broadsoft server.
Avaya: Must be used when registered to a Avaya Communication
Manager.
URI
Key in the URI of the E20 unit.