Specifications

D14330.06 ADMINISTRATOR GUIDE TANDBERG E20July 2009
14
Whats in this Guide? Introduction Getting Started Using E20 The Settings Advanced settings
Getting started
Setting up the E20 from remote
First you should choose a name for your unit. Use a name that is unique to
avoid conflicts. The recommendation would be to incorporate your name or
initials, eg. AliceWonderland.
xConguration SystemUnit Name: “AliceWonderland
Note that in most most cases DHCP will be used for assignment:
xConguration Network 1 Protocol: “IPv4
xConguration Network 1 Assignment: “DHCP”
If not, you may want to set your IP network settings manually:
xConguration Network 1 IPv4 Address: “<Your-IP-Address>
xConguration Network 1 IPv4 Gateway:<Network-Gateway-IP-Address>
xConguration Network 1 IPv4 Subnetmask: “<SubNet-mask>”
xConguration Network 1 DNS Domain Name: “<local domain names>
xConguration Network 1 DNS Server 1 Address: <DNS Server IP Address>
For remote administration the following settings are recommended. This
should also make the system visible in TMS.
xConguration Provisioning Mode: Tms
xConguration Provisioning ExternalManager Address: “<hostname
of your tms server>”
xConguration Provisioning ExternalManager Protocol: Http
xConguration Provisioning ExternalManager Path: “tms/public/
external/management/systemmanagementservice.asmx”
To be able to dial, you need to configure the SIP settings.
xConguration NetworkServices SIP Mode: On
xConguration SIP Prole 1 DefaultTransport: Auto
xConguration SIP Prole 1 Type: Auto
xConguration SIP Prole 1 Proxy 1 Discovery: Manual
xConguration SIP Prole 1 Proxy 1 Address: “<ip of your SIP
server”
xConguration SIP Prole 1 URI: “<your SIP URI>
If your SIP Server/PBX uses user authorization you need to supply a user-id
and password
xConguration SIP Prole 1 Authentication 1 LoginName: <your
user-name>
xConguration SIP Prole 1 Authentication 1 Password: <password
You may want to use a corporate TMS phonebook. If you have this and no
entries are displayed after configuring, you must make sure that your unit is
registered in TMS and a phonebook is assigned to your system.
xConguration Phonebook Server 1 ID: “default”
xConguration Phonebook Server 1 Type: “TMS”
xConguration Phonebook Server 1 URL: “<URL to your phonebook
service>
Should the system fail to respond to incoming calls, make sure that:
• The system is connected to line voltage
• The LAN cable is properly connectedsee Connecting the E20 for details.
Your TANDBERG E20 comes with an empty administrator
password. We strongly recommend that you set up an
administrator password by using the menu in Settings > Advanced
> Change password.