Specifications
D14330.06 ADMINISTRATOR GUIDE TANDBERG E20—July 2009
13
What’s in this Guide? Introduction Getting Started Using E20 The Settings Advanced settings
Getting started
5. Go to Settings > Advanced > Advanced configuration > SIP >
Profile1. Set Default Transport to Auto (which is the same as default),
Proxy1 Discovery to Manual, You must also enter the IP address of
the Proxy (Proxy is your PBX/VCS or OCS) and you must enter the URI
of your E20. Set the SIP Mode back to On.
6. If your SIP Server/PBX uses user authorization you need to supply
a user-id and password. This is done in Settings > Advanced >
Advanced Configuration > SIP > Profile1 > Authentication 1.
7. You may want to use a TMS phonebook. If you have this and no entries
are displayed after configuring, you must make sure that your unit is
registered in TMS and a phonebook is assigned to your system.
Using the keypad to configure the E20
There are two ways of setting up the E20—by using the keypad or by
logging into the unit from remote. This page explains how to set up the
unit using the keypad, while how to set it up from remote is explained
on the next page.
Press the
Home key to produce the Home menu and navigate down to
Settings. Press the RigHt aRRow key to produce the Settings menu and
navigate down to Advanced. Press the RigHt aRRow key.
Finally navigate down to Advanced configuration and press the
RigHt
aRRow key again. Navigation like this will hereinafter be shown as
Settings > Settings > Advanced > Advanced configuration.
1. Navigate to SystemUnit > Name and press
enteR.
Select a name that is unique to avoid conflicts. We recommend
that you use your name or initials, eg. AliceWonderland. This name
will be seen as you by the others.
2. In most cases DHCP will be used for assignment:
Go to the previous menu—the Advanced (use
Left aRRow key) and
navigate to IP Settings > IP Assignment, if the cursor is not there
already. Press enteR and set to DHCP.
Alternatively, set it to Static and enter the IP address, Subnet
Mask and Gateway IP address.
3. For remote administration the below settings are recommended.
This should also make the system visible in TMS.
In the Settings > Advanced > Advanced configuration >
Provisioning > ExternalManager set Address, Protocol, Path and
Mode, which will be TMS, if used.
4. To be able to dial, you need to configure the SIP settings.
In the Settings > Advanced > Advanced configuration >
NetworkServices > SIP, set SIP Mode to Off before doing
anything else.
Your TANDBERG E20 comes with an empty administrator
password. We strongly recommend that you set up an
administrator password by using the menu in Settings > Advanced
> Change password.