Datasheet

Data Sheet
All contents are Copyright © 1992–2007, 2009 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 2 of 5
Connectors and Cabling
Equipment: standard SFP interface network: dual LC/PC connector
Note: Only connections with patch cords with PC or UPC connectors are supported. Patch
cords with APC connectors are not supported.
All cables and cable assemblies used must be compliant with the standards specified in the
standards section.
Environmental Conditions and Power Requirements
Operating temperature range: 32 to 158°F (0 to 70°C )
Storage temperature range: –40 to 185°F (–40 to 8 C)
Dimensions
Dimensions (H x W x D): 8.5 x 13.4 x 56.5 mm
Cisco SFPs typically weigh less than 75 grams.
Table 1 describes the electrical power interface details, and Table 2 describes optical parameters.
Table 1. Electrical Power Interface Data
Parameter Symbol Minimum Typical Maximum Units
Supply Current I
s
200 300 mA
Surge Current I
Surge
30 mA
Input Voltage V
cc
3.1 3.3 3.5 V
Table 2. Optical Parameters
Parameter Symbol Minimum Typical Maximum Units Notes and Conditions
Transmitter
Spectral Width 0.2 nm Full width, –20dB
from maximum, with
resolution bandwidth
(RBW) = 0.01 nm
Transmitter
Center
Wavelength
x – 100 x x + 100 pm Refer to Table 4 for
center wavelengths
Side-Mode
Suppression
Ratio
SMSR 30 dB
Transmitter
Extinction
Ratio
OMI 8.2 dB
Transmitter
Optical Output
Power
P
out
0 4.0 dBm Average power coupled
into single-mode fiber
Receiver
Receiver
Optical Input
Wavelength
1530 1565 nm
Receiver
Damage
Threshold
+5 dBm
Power-Limited Performance at OSNR of 20 dB (1 GbE or 1-Gbps FC) or 21 dB (2 Gbps FC) at 0.1-nm RBW
Optical Input
Power
P
in
–28.0 –9.0 dBm