Installation guide

33
Cisco MDS 9000 Family Release Notes for Cisco MDS NX-OS Release 5.2(6)
OL-27554-01
Limitations and Restrictions
Configuring a Persistent FCID in an IVR Configuration with Brocade Switches, page 39
SME Quorum
You cannot change the quorum or the SME master node during a master key rekey. If a change occurs
during the smart card portion of the operation, the master key rekey operation will fail and must be
repeated from the beginning.
OUI Mismatch for SME Tape Targets
If Cisco DCNM does not discover all expected tape targets, check the sme.log to identify an OUI
mismatch. Look for a message like the following:
2012.04.09 21:15:50 WARN [SME] skipped target 50:06:0b:00:00:b8:e4:b0 due to explicit
type mismatch. Expect: 240 found: 228. If this is an error update your OUI definitions
To correct this issue, manually add the OUI definitions to the server.properties file. The format is as
follows:
# 0xhhhhhh vendor_name devicetypes h(host)|d(disk)|t(tape)|s(switch)|g(gateway)|m(cisco
mds)
# for example: newOUIs=0x00E069 JNI h|d; 0x000ded Cisco m;\
# 0x006069 Brocade s;
newOUIs=
FCIP Performance Drop
FCIP performance can drop in a topology where the round-trip time (RTT) delay is configured at 80 ms,
IPSec is enabled, and write acceleration (WA) is not used.
FCoE Module
In Cisco MDS NX-OS Release 5.2(x), you cannot install a FCoE module in a switch that is running
DMM, SME, or IOA.
Link traps for FCoE devices are sent only when a VFC interface flaps.
IPv6
The management port on Cisco MDS switches supports one user-configured IPv6 address, but does not
support auto-configuration of an IPv6 address.
User Roles
In SAN-OS Release 3.3(x) and earlier, when a user belongs to a role which has a VSAN policy set to
Deny and the role allows access to a specific set of VSANs (for example, 1 through 10), the user is
restricted from performing the configuration, clear, execute, and debug commands which had a VSAN
parameter outside this specified set. Beginning with NX-OS Release 4.1(1b), these users are still